Fast And Effective Visual Inspection
Fast And Accurate Optometry Process
Optometry Process Steps:
1.Consultation
Age, occupation and living habits
Visual status, history of wearing glasses, family history of eyes
Wearing situation of original glasses
2.Objective Inspection
Retinoscopy or autorefraction
3.Subjective Optometry
1. Verify objective inspection data
2. Fog vision
3. Preliminary inspection of astigmatism axial degree
4. Red green balance test
5. Fine astigmatism axis and degree
6. Red and green again
7. Binocular balance
8. Fog vision again
Inspection Of Visual Function
Visual function inspection includes many inspections, but when there are many customers and time is not allowed, the store can first check the customer accommodation facility and convergence facility during visual function inspection.
Visual Function Inspection Process:
1. Accommodation Facility
2. Convergence Facility
Tools: Prism flipper,near vision card
Inspection Of Convergence Facility
Steps:
1. The diopter is normal or wear the universal trial frame with corresponding diopter lens inserted to complete diopter correction.
2. Insert the 3△BI prisms and 12△BO prisms into the flipper and adjust the pupil distance.
3. Adjust the adjustment ruler and place the corresponding vision chart at a distance of 40㎝ from eyes.Ask the examinee to look at the single row vision chart.
4. Place the flipper with 3△BI prisms in front of the eyes until the visual chart merge into one column.
5. Replace the flipper with 12△BO prisms in front of the eyes and start timing.Ask the examinee to look at the single row vision chart and try to complete fusion. After the fusion, replace the flipper with 3△BI prisms until complete fusion again.It is a replacement period.
6. Measure the replacement period completed by the measured eyes within one minute.
7. The normal binocular convergence facility is 12~18 times per minute.
After checking accommodation facility and convergence facility, if time permits, then check the eye position, fusion function, AC / A, amplitude of accommodation, accommodation force, near point convergence, etc
Establishment Of Customer's Refraction File
Main contents of eye health archives:
1. Consultation record
2. Naked vision, daily life vision and better corrected vision
3. Record the diopter.
4. Visual function inspection data
5. Corneal refractive power, radius of curvature, axial length, anterior chamber depth and intraocular pressure were measured at the same time.
A good optometry and glasses store will improve a series of detailed processes from filing, training, tracking, review and return visit, and establish customer trust and loyalty, which will also make the store better and better.
1. Accommodation Facility
2. Convergence Facility
Tools: Prism flipper,near vision card
1. The diopter is normal or wear the universal trial frame with corresponding diopter lens inserted to complete diopter correction.
2. Insert the 3△BI prisms and 12△BO prisms into the flipper and adjust the pupil distance.
3. Adjust the adjustment ruler and place the corresponding vision chart at a distance of 40㎝ from eyes.Ask the examinee to look at the single row vision chart.
4. Place the flipper with 3△BI prisms in front of the eyes until the visual chart merge into one column.
5. Replace the flipper with 12△BO prisms in front of the eyes and start timing.Ask the examinee to look at the single row vision chart and try to complete fusion. After the fusion, replace the flipper with 3△BI prisms until complete fusion again.It is a replacement period.
6. Measure the replacement period completed by the measured eyes within one minute.
7. The normal binocular convergence facility is 12~18 times per minute.
1. Consultation record
2. Naked vision, daily life vision and better corrected vision
3. Record the diopter.
4. Visual function inspection data
5. Corneal refractive power, radius of curvature, axial length, anterior chamber depth and intraocular pressure were measured at the same time.