1 | Flat panel detector |
1.1 | Amorphous silicon wired flat panel detector |
1.2 | Effective pixels: 9,<> |
1.3 | Pixel matrix: 3071*3071 pixels |
1.4 | A/D conversion: 16 bits |
1.5 | Effective Area: 17"×17" |
1.6 | Spatial resolution: 3.7 l/mm |
1.7 | Imaging time: 6.82s |
2 | Mechanical structure: intelligent electric double column |
2.1 | Bracket movement mode: electric |
2.2 | Vertical range (tube assembly): 1400mm (range: 400mm~1800mm) |
2.3 | Horizontal range: 1200mm |
2.4 | Tube assembly rotation range: 360° |
2.5 | Vertical range (detector assembly): 1400mm (range: 400mm~1800mm) |
2.6 | Intelligent collision avoidance system (intelligent protection) |
2.7 | Intelligent Automatic Height Recognition System (Smart POS) |
3 | High voltage generators |
3.1 | Maximum operating frequency: 200kHz |
3.2 | Power: 50kW |
3.3 | kV range: 40kV -150kV |
3.4 | mA range: 10mA -630mA |
3.5 | mAs range: 0.1mA -630mA |
3.6 | High-voltage generator intelligent network voltage real-time monitoring system (intelligent monitoring) |
4 | X-ray tube |
4.1 | Focus size: 0.6mm/1.2mm |
4.2 | Focus power: Small focal length: 20kW Large focal length: 50kW |
4.3 | Maximum heat capacity: 230kHU |
4.4 | Maximum peak voltage: 150kV |
4.5 | Anode speed: 2700 rpm |
4.6 | Anode heat dissipation rate: 667HU/s |
5 | Filter grid |
5.1 | Ratio: 10:1 |
5.2 | Focus distance: 100 cm |
5.3 | Size: 18inch * 18inch |
5.4 | Fixed type |
6 | LED Collimator |
6.1 | The time limit of the indicator: 30±3s |
6.2 | Radiation field indicator: 150W, 24VAC |
6.3 | Inherent filtration: 1.0 mm Al. EQ. |
7 | Table |
7.1 | Photoelectric controlled four-way suspended table |
7.2 | Length ×wide of table surface:2200*800mm |
7.3 | Movement stroke (longitudinal):840mm |
7.4 | Movement stroke (horizontal):240mm |
7.5 | Movement range of detector(horizontal):400mm |
7.6 | Bed height:700mm |
7.7 | Load bearing:≥200kg |
7.8 | Bed-detector distance:80mm |
8 | Workstation |
8.1 | DELL 5050MT,Intel Pentium G4560 processor, 4G/500G/DVDRW/WIN10,E2216H 21.5 inch high contrast display |
8.2 | Software function(DR workstation software can control the stand) Intelligent control system: You can control the operation of the stand freely through computer software, and control the movement and rotation of the tube. |
8.3 | Software function(software direct exposure control) |
8.3.1 | Support customization for dose template; |
8.3.2 | The selection part and position template, automatically bring out the matching dose; it can also provide early warning when voltage fluctuation is large; Selection shape of the patient, automatically select the matching dose, and adjust to the dose online; |
8.3.3 | Control the size of focus; |
8.3.4 | Display generator's status transparent; |
8.3.5 | Refusal and acceptance of images; |
8.3.6 | Support automatic sending of images. |
8.3.7 | AEC: optional |
8.3.8 | Image stitching: optional |
8.4 | Software function(patient management) |
8.4.1 | Remote direct access to patient information in RIS with worklist protocol; Manually create the patient examination information; |
8.4.2 | Emergency quick registration; |
8.4.3 | Simple, advanced, or custom data query methods; The image CD burning in Dicom standard , can be viewed on any standard image workstation; |
8.4.4 | Inquiry and management of historical image data; |
8.4.5 | Detection of disk space, automatic cleaning of old check data; |
8.4.6 | Dicom transmission of image and seamless connection with PACS; Support diagram text report, carry report library; |
8.4.7 | Print patient reports, exposure times can be displayed in the list of patients; The original image is easy to view. |
8.4.8 | Software function(image processing) |
8.5.1 | Supports dual or multi-screen images display; Manually/automatically/preset window width and window level, partial window width, and window level; |
8.5.2 | Operation positive and negative of the image, flip image, rotation image, scaling image, and roaming; |
8.5.3 | Automatic or manual addition of image information; |
8.5.4 | Line, angle, rectangle, ellipse, polygon, and other measuring tools; Balance tissue, enhancement contrast, optimization dose; |
8.5.5 | Enhancement edge: automatic recognition and analysis of images, enhance edge sharpness. |
8.5.6 | Preview the post-processing image 1:1: the doctors make a more intuitive diagnosis in image optimization; |
8.5.7 | CAD View: just click the mouse, and doctors can see the details of the image more clearly so that doctors can make more accurate diagnoses. |
8.6 | Software function(film printing) |
8.6.1 | Set film properties, image layout, and printing mode; |
8.6.2 | Typeset quickly by manual/automatic ; |
8.6.3 | Select any camera within the network; |
8.6.4 | Customization of patient information and display location; |
8.6.5 | Support for queue management; Support for setting print priority. |
9 | Optional functions |
9.1 | AEC -- Automatic exposure control technology: Accurate and efficient dose management; Improve the image quality; Easy Operation. |
9.2 | Image stitching: Seamless stitching, smooth and natural. |
9.3 | EE-PACS: A very powerful PACS system, using B/S architectural design and based on international DICOM and HL7standards. It is designed and optimized for high workflow efficiency and productivity, as well as friendly and intuitive user interfaces. It provides a rich set of modules to meet your daily needs. |
Processing time
According your order list. we will supply delivery time .
Commonly is 5-7 work days after we confirm payment
Shipping time
By Express : 3-7 days . Door to door service
By Air : 3-7 days . (the goods arrival at your local air ports
By sea : 30-40 days (the goods arrival at your local sea ports )
PS : by air or by sea, if you need door to door service, please tell us . we will help you checking the extra door to door cost.
How many months warranty do you provide ?
one year
What should I do if the machine have question ?
For ensuring all the items are in good quality, we will test all products before the packages were sent out. Once the machine have some question, please don't worry. kindly send us some images of the situation , Video and machine series, and explain the question in where . we will supply solution to you deal soon.
What should I do if the spare parts is broken in Warranty ?
If in Warranty, some spare parts broken in the Use. kindly supply picture or video , and machine series number .
We will send the spare parts by express to you soon.. and we bear express cost .
Please enter your target price
Please provide a quantity
United States
Please provide your name
Please enter your email adress
Enter a valid email address
Please enter the phone number
Please enter the inquiry information
Moving Door Medicine Cabinet AG-SS003-2
TBT-067 Trash Can Without Cover
Multi-purpose cleaning vehicle AF08170
TBT-099 Foot-Operated Trash Can
AG-SS001 Hospital Wardrobe With Nine Units For Changing Clothes(Iron spray material)
AG-SS002-1 Steel Material Wardrobe With Three Units For Changing Clothes
TBT-105 Foot-Operated Trash Can
LINK-PP LPJ1075-1BHNL 100% Cross RTA-110AHQ1A UDE
United States
Carrier
CostDelivery TimeTracking
Medical Digital Radiography Systems-Double Column DR System AG-Staray 500